Model | ZMMFC 5.5.1 | |||
Input Power Supply | 230V AC @ 50Hz. | |||
Input Protection | Calibrator is Protected by I/P OV (Over Voltage) & I/P UV (Under Voltage) | |||
DC Voltage Ranges | 200mV, 2V, 20V, 200V, 1000V | |||
AC Voltage (45Hz to 1000Hz) Ranges | 200mV, 2V, 20V, 200V, 1000V | |||
DC Current Ranges | 2mA, 20mA, 200mA, 2000mA, 20A | |||
AC Current (45Hz to 1000Hz) Ranges | 2mA, 20mA, 200mA, 2000mA, 20A | |||
Frequency Range | 45Hz to 1000Hz | |||
Accuracy @ 20oC to 28oC, RH <75% | AC Voltage: 0.15% ±15 Digit | DC Voltage: 0.1% ±5 Digit | Frequency: ±0.1 Hz | |
AC Current: 0.2% ±15 Digit | DC Current: 0.2% ±5 Digit | |||
Operating Temperature | 10oC to 40oC | |||
Power OFF Storage Temperature | 5oC to 70oC | |||
Required Earth to Neutral | Less than 1 V AC | |||
Drift due to ageing | 50 PPM per year. | |||
Short term stability of the set value | 350 PPM | |||
Display | 5½ Digit 7 segment red LED display for Voltage & Current | |||
4 Digit 7 segment red LED display for Frequency | ||||
Selection of AC/DC Parameters | By up and down keys and bar of LED to indicate selected parameter | |||
Selection of Ranges | By up and down keys and bar of LED to indicate selected range | |||
Setting of Voltage & Current | By decade switch | |||
Setting of Frequency | By multi turn potentiometer | |||
Dimension & Weight | 550mm(W) X 600mm(D) X 170mm(H) | 32kg. (Approx.) |