Multi Function Calibrator, Calibrators, High Voltage Breakdown Tester, Ac Dc Regulated Power Supply, Electronic Test and Measuring Instruments, Equipments, Meter for Ups, Inverters, Variac Digital, Digital Ups, Stabilizer, Genset Scanner

 
Digital UPS, Stabilizers, Genset Scanners
   
Dimension (96 x 96 x 50 ) mm
Panel Cutout ( 92 x 92 ) mm
Power + 5 V , Com. , - 5 V
Operating Temp. Ambient to 65o C
Features  
   
  • Electrical Isolation between all parameters
  • Parameter Selection by Push Button Select Switch & bar of LEDs
  • Gain, Offset setting for all parameters are accessible.
   
Specification  
   

Parameter

Range

Accuracy

Resolution

AC Voltage 0 to 450 V AC ( 0.75 % rdg + 1 dgt) 1 Volt
AC Current As Per CT ratio ( 0.75 % rdg + 1 dgt) 0.1 Amp.
Frequency 48 to 52 Hz + 2 dgt) 0.1 Hz
DC Voltage 0 to 500 V DC ( 0.75 % rdg + 1 dgt) 1 volt
DC Current  As per shunt ratio ( 0.75 % rdg + 1 dgt) 0.1 Amp.
   
 
   
Multi Function Calibrator, Multi Function Calibrators, Electronic Test and Measuring Instruments, Process Control Instruments, Calibration & Repairs of Instruments, AC DC High Voltage Breakdown Testers, Digital Panel Meter, DC Regulated Power Supply Linear & SMPS, Digital UPS, Stabilizer, Genset Scanner, UPS Annunciator, Digital Panel Meters, Battery Charger, Digital Variac, Insulation Resistance Tester, Transistor Zener, Diode Tester
   
Power 9 V/0.5 A, 9 V/0.1A and 17V/0.1A isolated.
Display LCD (16x2) with Back Light
Configuration 1f to 1f , 3f to 1f , 3f to 3f
   
Specifications:  
   

parameter

Range

Accuracy

I/P AC Voltage 230 V or 440 V +/- (1.5%rdg + 1dgt)
I/P AC Current As per CT ratio +/- (1.5%rdg + 1dgt)
I/P AC Frequency 47 to 53 Hz +/- 1dgt
O/P AC Voltage 230 V or 440 V +/- (0.75%rdg + 1 dgt)
O/P AC Current As per CT ratio +/- (1.5%rdg + 1dgt)
O/p Frequency 47 to 53 Hz +/- 1dgt
Battery Voltage 0 to 500 VDC +/- (0.75%rdg + 1dgt)
Battery Current As per shunt ratio +/- (0.75%rdg + 1dgt)
   
  • Key Pad : Only 3 keys to program and monitor the UPS Parameters.
  • Trip Signal and Alarm : Inverter Trip Signal with Alarm when fault conditions occurs : O/P Over Voltage, O/P Under Voltage, O/P overload, Battery Over Voltage, Battery Under Voltage. Annunciator beeps buzzer when the Battery voltage is low.
   
 
 

Multi Function Calibrator, Multi Function Calibrators, Electronic Test and Measuring Instruments, Process Control Instruments, Calibration & Repairs of Instruments, AC DC High Voltage Breakdown Testers, Digital Panel Meter, DC Regulated Power Supply Linear & SMPS, Digital UPS, Stabilizer, Genset Scanner, UPS Annunciator, Digital Panel Meters, Battery Charger, Digital Variac, Insulation Resistance Tester, Transistor Zener, Diode Tester

 
Digital Panel Meters
Digital Panel Meters
Sr. No.  Description  Accuracy  Size
01  3 1/2 Digital DC Voltmeter  ( 0.5 % rdg + 1 dgt )  48 x 96 x 90
02  3 1/2 Digital DC Ammeter  ( 0.5 % rdg + 1 dgt )  48 x 96 x 90
03  3 1/2 Digital AC Voltmeter  ( 0.75 % rdg + 1 dgt )  48 x 96 x 90
04  3 1/2 Digital AC Ammeter  ( 0.75 % rdg + 1 dgt )  48 x 96 x 90
05  3 1/2 Digital AC True RMS 
 Voltmeter
 ( 0.75 % rdg + 1 dgt )  48 x 96 x 90
06  3 1/2 Digital AC True RMS 
 Ammeter
 ( 0.75 % rdg + 1 dgt )  48 x 96 x 90
07  3 Digit Line Frequency Meter  1 dgt  48 x 96 x 70
08  4 Digit Line Frequency Meter  1 dgt  48 x 96 x 70
09  RPM  Indicator  1 dgt  48 x 96 x 70
   
Also available 4 1/2 digit meter size (48x96x120)mm

Also All meters are available in Size 96 X 96 mm
 
Designed by : MID  Hosted by : PBD  Promoted by : GID