Multi Function Calibrators, Watt Meter Calibrators, High Voltage Breakdown Testers, DC Regulated Power Supply, Digital UPS, Stabilizers


MULTI FUNCTION CALIBRATORS / VOLTAGE & CURRENT STANDARDS

   
Power 230V, 1A, 50/60 Hz +/- 10%
Operating Temperature 25 +/- 30C, RH<70%
Display
  For AC/DC Voltage and Current :4 1/2 Digit LED
  For Frequency : 4 Digit LED
Selection of Function By Up Down keys and bar of LEDs.
Selection of Ranges By Up Down keys and bar of LEDs.
Setting of V or A and Hz By multi turn potentiometers.
   
Specifications :
 
Parameter Ranges Accuracy
DC Voltage 200m, 2,20,200,1000, Volt +/-(0.1% rdg +10 digit)
* DC Current 2m, 20m, 200m,2,10 Amp +/-(0.1% rdg +10 digit)
AC Voltage (45 to 1000 Hz) 200m,2,20,200,900 Volt +/-(0.15% rdg +10 digit)
* AC Current (45 to 1000 Hz) 2m, 20m, 200m, 2,10 Amp +/-(0.15% rdg +10 digit)
Extended Current Range for Clamp On Meter :
( AC or DC ) Usiging x 100 Current Coil
1000 Amp +/-(0.25% rdg +15 digit)
    
* For 10 Amp Ranges Accuracy = 0.15% +/- 5 digit

Features :

• Stability suitable to calibrate DMM, DPM, Clamp Meters and Analog Meters
• Pure Sine wave for  AC Voltage and AC Current with variable frequency
• Short Circuit and Overload Protection
• Safe for User and unit under calibration

 
WATT METER CALIBRATORS
   
WATT METER CALIBRATORS
   
Input Power 230V AC, 50/60 HZ
AC Voltage ( 50 Hz) Range 0 to 500V
AC Current (50 Hz) Range 0 to 10 Amp
Power Factor Range 0.5 to unity ( Lag & Lead)
Wattmeter Range 0 to 5000 Watt( Multiplication of V, A and PF)
Accuracy( at 250C, RH< 70 %)  
AC V 0.15%
AC Amp 0.15%
Power Factor 0.2%
Watt 0.35%
   
Features : -
  • Overload and short circuit protection.
  • 4 1/2 digit meter to indicate set V, A, PF
  • Setting by Multi turn potentiometers.
   
   
HIGH VOLTAGE BREAKDOWN TESTERS
   
Digital Meter Accuracy for kV : 1.5% FS, for mA : 0.5%
Timer Positions : 3 Sec , 12 Sec, 30 Sec, 1 Min, 2 Min, 5 Min
Power Requirement 230 V AC, +/- 10% , 50/60 Hz
   
Features  
  1. Audio / Visual Alarm When HV ON & Off
  2. Test ON/ OFF switch to start and interrupt test.
  3. Unique Data Hold facility to hold Breakdown Voltage data.
  4. Precise Trip Current Setting or press to set switch for leakage current
  5. Inbuilt timer with selector switch.
   

Type

Maximum 
Test Voltage (kv)

Typical Leakage currents (mA)

Application (Industry sector)

AC HV Tester  5,10  20,100,350  Transformer, Control Panels,  
 UPS, Stabilizer etc.
DC HV Tester  5,10  20,100,350  Capacitor
AC/DC HV Tester  5,10  20,100,350  Transformer, Control Panels, 
 UPS, Stabilizer etc.
   
 
Variable Voltage / Current Source with Variable Frequency ( Single Phase & 3 Phase )
   
Multi Function Calibrator, Multi Function Calibrators, Electronic Test and Measuring Instruments, Process Control Instruments, Calibration & Repairs of Instruments, AC DC High Voltage Breakdown Testers, Digital Panel Meter, DC Regulated Power Supply Linear & SMPS, Digital UPS, Stabilizer, Genset Scanner, UPS Annunciator, Digital Panel Meters, Battery Charger, Digital Variac, Insulation Resistance Tester, Transistor Zener, Diode Tester
Variable Voltage / Current Source with Variable Frequency
   
Typical Technical Specification
   
Output Voltage Range : Single Phase or 3 Phase 0 to 440 V (for Voltage Source )
Output Current Source 0 to 100 A (for Current Source)
Output Wattage 12 kVA
Frequency Range 40 to 1000 Hz
Total Harmonic Distortion Less than 1.25% for Precision Voltage & Current Source. 3.5% for Power sources
Stability 0.1% (After Warm-up)
Output Power Up to 500 VA or as per customer requirement
Digital Meters 3 1/2 digit Voltage/Current 4 digit Frequency
Protection Overload and short circuit
Operating Temperature 25 + 100C
Line / Load Regulation 0.5 % for (230 + 10 %)
   
 
DC Regulated Power Supply ( Linear & SMPS )
   
DC Regulated Power Supply
DC Regulated Power Supply
   
Typical Technical Specification
   
Output Voltage Range 0 to 1000 V
Output Current 0 to 100 amp.
Output Maximum Wattage 5000 Watt
Load Regulation 0.05 % ( From No Load to Full Load)
Line Regulation 0.05 %
Ripple 0.1% m Vrms Max. ( With / Without Load)
Output Stability 0.1 % ( After Warm up of 20 minutes)
Digital Meter ( Separate Meter For DC Voltage & current)
Accuracy For Voltage  : 0.5 % +/- 1 dgt
  For Current  : 0.5 % +/- 1 dgt
Protection Overload & Short circuit
Operating Temperature 0 to 50o C
Input Power Requirement 230 V or 110 V +/- 10 % , 50 / 60 Hz
Features :

 
  • Above 100 W power supplies have triac based pre regulator.
  • Switching frequency above 100 KHz for SMPS.
 


 